Recieved:

01/09/2026

Accepted:

03/11/2026

Page: 

–

doi:

http://dx.doi.org/10.17515/resm2026-2094st0801rs

Views:

20

Numerical investigation into the axial performance of single and double skin CFST Columns: Influence of shear stud spacing and tube thickness

Bashar F. Abdulkareem1, Mustafa Musa Salih1, Raid I. Khalel2, Nameer N. Salman3, Nooralmustafa Ali 3, Mahdi Karkush1

1Reconstruction and Projects Department, University of Baghdad, Baghdad, Iraq
2College of Civil Engineering, University of Technology, Baghdad, Iraq
3College of Engineering, Al-Nahrain University, Baghdad, Iraq

Abstract

This research presents the results of a finite element (FE) simulation conducted with the ABAQUS/CAE software. The goal of the project was to develop a simulation model that can predict the structural behavior of CFST columns (single or double skin) and studying the effect of shear stud spacing in double-skin columns. Findings were evaluated in comparison with documented experimental data in the existing literature (Younes et al., 2015). FE approach and the experimental data were in agreement with an average error of 2.4%; hence, the simulated model was deemed valid. Subsequently, the scope of numerical studies was expanded to encompass the examination of several factors, including the concrete skin type, the outer steel tube thickness, and the vertical spacing of studs. the capacity of double-skin columns was found to be between 4.8% and 6.6% higher than their single-skin counterparts. This may result from the selected dimensions of the samples and the inclusion of the internal steel tube, which enhances the column’s load-bearing capability. Reducing the vertical spacing of shear connectors leads to an increase in ultimate strength of 8.9% and 13.8% for single skin columns with spacings of 100 mm and 50 mm, respectively, in comparison to the single skin column with a spacing of 200 mm, and by 10.7% and 13.5% for double skin columns with spacings of 100 mm and 50 mm, respectively, when compared to the double skin column with a spacing of 200 mm. The vertical spacing of shear connections is inversely related to the ultimate load of the column.

Keywords

ABAQUS; CFST columns; Shear connectors; Axial loading; Double-skin CFST; Shear strength; Parametric study

Cite this article as: 

Share This Article
LinkedIn
X
Facebook
journal cover
News & Upcoming Events