This study evaluates the cyclic behavior of a full-scale, two-dimensional in-plane Precise Interlock Brick (PIB) wall prototype (3000 × 3000 mm) through experimental testing and numerical analysis. Experimental tests were conducted under cyclic loading in accordance with ASTM E2126-19, while nonlinear finite element analysis and pushover simulations were performed to develop capacity curves. The investigation focused on lateral load capacity, ductility, initial and post-elastic stiffness, and energy dissipation. The seismic demand curve was established based on the Indonesian earthquake map. The numerical results demonstrated trends consistent with the experimental findings, although the predicted maximum load capacity (82.80 kN) was 18.93% lower than the experimentally measured value (102.14 kN). The prototype exhibited a ductility factor of 2.17, indicating limited-to-moderate ductility, and an energy dissipation capacity of 30,382.73 kN·mm. The findings provide empirical data on the strength and stiffness characteristics of PIB walls, supporting the development and calibration of design-oriented analytical models and their integration into three-dimensional structural analyses. Furthermore, the demand-to-capacity ratio (DCR) results indicate that the tested prototype satisfies the adopted strength criterion for design spectral acceleration values (SDS) of up to 0.80g. Overall, PIB technology offers a promising solution for rapid and efficient housing construction while maintaining structural performance in accordance with design standards.