Exploring the limits of flexural FRP strengthening in shear dominated reinforced concrete T beams

Yahia Taguia1, Youcef Si Youcef2, Sofiane Amziane3

1Université des Sciences et de la Technologie Houari Boumediene, Algeria
2Ecole Polytechnique d’Architecture et d’Urbanisme, Algeria
3Université Clermont Auvergne, Clermont Auvergne INP, CNRS, Institut Pascal, F-63000 Clermont- Ferrand, France

Abstract

The greatest challenge in strengthening deep reinforced concrete beams is overcoming brittle shear failure. Premature shear failure limits reliable flexural strengthening by preventing the full structural capacity of FRP reinforcement from being mobilized. To address this limitation, 36 RC T-beams with low shear span-to-depth ratios (a/d < 2.5), including under- and over-reinforced sections, were experimentally investigated. The beams were strengthened using externally bonded CFRP and bidirectional E-glass woven roving GFRP composites, the latter systematically evaluated as an economical strengthening alternative. An innovative NSM technique employing epoxy-impregnated rolled FRP sheets inserted into pre-cut grooves, acting similarly to conventional NSM FRP bars, was also developed. The experimental results showed that the effectiveness of FRP strengthening depended strongly on the reinforcement configuration and the governing failure mechanism. While selected configurations produced significant improvements in load-carrying capacity, ductility, and energy absorption, the tested beams predominantly exhibited diagonal cracking and brittle shear-dominated failure, which limited the full utilization of the FRP reinforcement. Across the four experimental series, the investigated FRP configurations produced a maximum 49.01% increase in load-carrying capacity, achieved with the U ±45° configuration, demonstrating the effectiveness of inclined FRP reinforcement in intercepting shear cracks and improving stress transfer. In terms of ductility, the configuration combining longitudinal reinforcement for the opening with 45° cross reinforcement exhibited the most pronounced improvement, with a 220.7% increase in energy-based ductility relative to the control beam. These findings demonstrate that, although FRP strengthening can substantially enhance the structural response of deep RC T-beams, shear remains a critical limiting mechanism. Integrated flexural shear strengthening is therefore essential to fully exploit the capacity of FRP systems in shear-dominated deep RC T-beams.

Keywords

RC beam; CFRP; GFRP; Shear; NSM; Flexural; Strengthening; T-Beams

Cite this article as: 

Share This Article
LinkedIn
X
Facebook
journal cover
News & Upcoming Events